5H500
FMWORLD
Availability: | |
---|---|
Quantity: | |
Model | 5H-500L |
Structure type | Continuous |
Drying method | indirect heating |
Dryer body dimensions (length x width x height) (mm) | 4320*7040*31950 |
Daily processing capacity (t/d) | 800 |
Precipitation range (%) | ≥14(corn)≥5(rice)≥8(wheat, soybean) |
Number of drying sections (units) | 3/4500mm |
Number of slow Su sections (pieces) | 3 |
Cooling section height (mm) | 2700 |
Dryer net volume (m³) | 200 |
Hot air temperature range (°C) | 30-140 |
No. 1 hot air blower model name | Centrifugal fan |
No. 1 hot air blower wind pressure (Pa) | 2200-2600 |
Flow rate of No. 1 hot air blower (m3/h) | 75000 |
No. 1 hot air blower motor power (kW) | 55 |
No. 2 hot air blower model name | Centrifugal fan |
No. 2 hot air fan wind pressure (Pa) | 2200-2600 |
Flow rate of No. 2 hot air blower (m³/h) | 75000 |
No. 2 hot air blower motor power (kW) | 55 |
No. 3 hot air blower model name | Centrifugal fan |
No. 3 hot air blower wind pressure (Pa) | 2200-2600 |
Flow rate of No. 3 hot air blower (m³/h) | 75000 |
No. 3 hot air blower motor power (kW) | 55 |
Cooling fan model name | Centrifugal fan |
Air cooler pressure (Pa) | 1100-1650 |
Cooler flow (m³/h) | 25000-40000 |
Cooling fan motor power (kW) | 22 |
Hot air stove model name/fuel type | JLR-10/coal, biomass pellets |
Hot air stove thermal power (heat output) (kJ/h (Kcal/h)) | 25000000 (6000000) |
Hot blast furnace smoke fan model name | Y5-47 No.11.D/Centrifugal fan |
Hot blast furnace smoke fan motor power (kW) | 45 |
Model | 5H-500L |
Structure type | Continuous |
Drying method | indirect heating |
Dryer body dimensions (length x width x height) (mm) | 4320*7040*31950 |
Daily processing capacity (t/d) | 800 |
Precipitation range (%) | ≥14(corn)≥5(rice)≥8(wheat, soybean) |
Number of drying sections (units) | 3/4500mm |
Number of slow Su sections (pieces) | 3 |
Cooling section height (mm) | 2700 |
Dryer net volume (m³) | 200 |
Hot air temperature range (°C) | 30-140 |
No. 1 hot air blower model name | Centrifugal fan |
No. 1 hot air blower wind pressure (Pa) | 2200-2600 |
Flow rate of No. 1 hot air blower (m3/h) | 75000 |
No. 1 hot air blower motor power (kW) | 55 |
No. 2 hot air blower model name | Centrifugal fan |
No. 2 hot air fan wind pressure (Pa) | 2200-2600 |
Flow rate of No. 2 hot air blower (m³/h) | 75000 |
No. 2 hot air blower motor power (kW) | 55 |
No. 3 hot air blower model name | Centrifugal fan |
No. 3 hot air blower wind pressure (Pa) | 2200-2600 |
Flow rate of No. 3 hot air blower (m³/h) | 75000 |
No. 3 hot air blower motor power (kW) | 55 |
Cooling fan model name | Centrifugal fan |
Air cooler pressure (Pa) | 1100-1650 |
Cooler flow (m³/h) | 25000-40000 |
Cooling fan motor power (kW) | 22 |
Hot air stove model name/fuel type | JLR-10/coal, biomass pellets |
Hot air stove thermal power (heat output) (kJ/h (Kcal/h)) | 25000000 (6000000) |
Hot blast furnace smoke fan model name | Y5-47 No.11.D/Centrifugal fan |
Hot blast furnace smoke fan motor power (kW) | 45 |