5H800
FMWORLD
Availability: | |
---|---|
Quantity: | |
Model | 5H-800L |
Structure type | Continuous |
Drying method | indirect heating |
Dryer body dimensions (length x width x height) (mm) | 4920*7640*31950 |
Daily processing capacity (t/d) | 800 |
Precipitation range (%) | ≥14(corn)≥5(rice)≥8(wheat, soybean) |
Number of drying sections (units) | 3/5400mm |
Number of slow Su sections (pieces) | 3 |
Cooling section height (mm) | 2700 |
Dryer net volume (m³) | 350 |
Hot air temperature range (°C) | 30-140 |
No. 1 hot air blower model name | Centrifugal fan |
No. 1 hot air blower wind pressure (Pa) | 2300-2700 |
Flow rate of No. 1 hot air blower (m3/h) | 105000 |
No. 1 hot air blower motor power (kW) | 90 |
No. 2 hot air blower model name | Centrifugal fan |
No. 2 hot air fan wind pressure (Pa) | 2300-2700 |
Flow rate of No. 2 hot air blower (m³/h) | 105000 |
No. 2 hot air blower motor power (kW) | 90 |
No. 3 hot air blower model name | Centrifugal fan |
No. 3 hot air blower wind pressure (Pa) | 2300-2700 |
Flow rate of No. 3 hot air blower (m³/h) | 105000 |
No. 3 hot air blower motor power (kW) | 90 |
Cooling fan model name | Centrifugal fan |
Air cooler pressure (Pa) | 1100-1650 |
Cooler flow (m³/h) | 35000-50000 |
Cooling fan motor power (kW) | 45 |
Hot air stove model name/fuel type | LR-16/coal, biomass pellets |
Hot air stove thermal power (heat output) (kJ/h (Kcal/h)) | 45000000(10800000) |
Hot blast furnace smoke fan model name | Y5-47 No.11.D/Centrifugal fan |
Hot blast furnace smoke fan motor power (kW) | 55 |
Model | 5H-800L |
Structure type | Continuous |
Drying method | indirect heating |
Dryer body dimensions (length x width x height) (mm) | 4920*7640*31950 |
Daily processing capacity (t/d) | 800 |
Precipitation range (%) | ≥14(corn)≥5(rice)≥8(wheat, soybean) |
Number of drying sections (units) | 3/5400mm |
Number of slow Su sections (pieces) | 3 |
Cooling section height (mm) | 2700 |
Dryer net volume (m³) | 350 |
Hot air temperature range (°C) | 30-140 |
No. 1 hot air blower model name | Centrifugal fan |
No. 1 hot air blower wind pressure (Pa) | 2300-2700 |
Flow rate of No. 1 hot air blower (m3/h) | 105000 |
No. 1 hot air blower motor power (kW) | 90 |
No. 2 hot air blower model name | Centrifugal fan |
No. 2 hot air fan wind pressure (Pa) | 2300-2700 |
Flow rate of No. 2 hot air blower (m³/h) | 105000 |
No. 2 hot air blower motor power (kW) | 90 |
No. 3 hot air blower model name | Centrifugal fan |
No. 3 hot air blower wind pressure (Pa) | 2300-2700 |
Flow rate of No. 3 hot air blower (m³/h) | 105000 |
No. 3 hot air blower motor power (kW) | 90 |
Cooling fan model name | Centrifugal fan |
Air cooler pressure (Pa) | 1100-1650 |
Cooler flow (m³/h) | 35000-50000 |
Cooling fan motor power (kW) | 45 |
Hot air stove model name/fuel type | LR-16/coal, biomass pellets |
Hot air stove thermal power (heat output) (kJ/h (Kcal/h)) | 45000000(10800000) |
Hot blast furnace smoke fan model name | Y5-47 No.11.D/Centrifugal fan |
Hot blast furnace smoke fan motor power (kW) | 55 |